2708 Reader
===========

This was just a quick & dirty build to read a few old Nascom 2708s.
Dont bother to build one, borrow mine. Once your 2708s are read, its redundant :)
Phil_G

2708 +12 and -5 come from two separate small 3S lipo batteries via JST connectors, -5v is via a 7905 reg
2708 +5 comes from the Nano
Ground is common

* MUST * apply -5 first (ie connect the -12v lipo first) and remove last

Connect Nano to USB port, there is a 5 second delay to allow the CH340G to be recognised
Use Teraterm or similar to spool the hex to a logfile for saving.

Baud rate is 9600 and output is standard Intel hex.
If you miss the file just press the Nano reset button to resend.

Connections:
2708		Nano
D0		D18/A4	(PC4)
D1		D19/A5	(PC5)
D2		D2	(PD2)
D3		D3	(PD3)
D4		D4	(PD4)
D5		D5	(PD5)
D6		D6	(PD6)
D7		D7	(PD7)

A0		D8	(PB0)
A1		D9	(PB1)
A2		D10	(PB2)
A3		D11	(PB3)
A4		D12	(PB4)
A5		D13	(PB5)
A6		D14/A0	(PC0)
A7		D15/A1	(PC1)
A8		D16/A2	(PC2)
A9		D17/A3	(PC3)

CE		GND
RD		GND